- Overview
- Technical data
- Accessories
- Certification
- Business data
- Download
Product advantages
☑ Safe isolation between coil and contacts☑ 6A maximum switching current
- 3D model
- Overview
- Dimension
- Coil side
- Environmental data
- Coil side
- Switch part (contact part)
- Standards/Regulations
3D model
Overview
| Test Voltage Relay Coils/Relay Contacts | 4000VAC/1min |
| Test voltage PDT/PDT | 1000VAC/1min |
| Operation mode | 100% work factor |
| Installation location | Arbitrary |
Dimension
| width | 5mm |
| length | 28mm |
| high | 15mm |
Coil side
| Coil resistance | 3388Ω |
| Power consumption at rated conditions | 0.40W |
Environmental data
| Ambient temperature (operation) | -40℃~+75℃ |
| Ambient temperature (storage/transport) | -40 °C ... +85 °C |
| environment humidity | 5%~85%RH |
Coil side
| Rated input voltage UN | 24VDC |
| Typical input current under UN | 22mA |
| Operating voltage | ≤75% |
| Reset voltage | ≥10% |
| Maximum allowable voltage | 1.1 |
Switch part (contact part)
| Contact voltage maximum | 277VAC/30VDC |
| Contact current maximum | 6A |
| Contact composition | 1C |
| Contact mechanism | single |
| Contact material | Ag alloy |
| Contact resistance | ≤100mΩ |
| Action time | <8ms |
| Reset time | <4ms |
| Maximum switching frequency (mechanical) | 18000 times/h |
| Maximum switching frequency (rated load) | 1800 times/h |
| Insulation resistance | ≥100MΩ |
| Withstand voltage (between coil and contact) | 4000VAC/1min |
| Withstand voltage (between contacts of the same pole) | 1000VAC/1min |
| Shock proof | 10G |
| Vibration resistant | 10-55Hz |
| Electrical life | >1×105 |
| Mechanical life | >1×107 |
Standards/Regulations
| Standards/Regulations | IEC 61810-1 IEC 60664 |
| insulation | Basic isolation |
| Pollution level | 3 |
| Overvoltage category | Ⅲ |
| Order number | 30070000096 |
| Packing unit | 50 STK |
| Minimum order quantity | 50 STK |
| Products weight (without packaging) | 17g |
Matching parts